MASSACHUSETTS Vocational Technical TEACHER TESTING Program

 

SCOPE OF TEST CODE # 43 – STATIONARY ENGINEERING

 

WRITTEN EXAM -100 QUESTIONS

 

TIME ALLOWED: 3 HOURS

PERCENT OF TEST:

 

5 % HEALTH AND SAFETY

 

2% STATIONARY ENGINEERING QUALITY STANDARD OPERATIONS

 

5 % STATIONARY ENGINEERING DIAGNOSTICS

 

10% EQUIPMENT MAINTENANCE AND MEASURE DEVICES

 

2 % MANUFACTURING PROCESS MANAGEMENT

 

26% STEAM BOILERS

 

25% FUEL BURNERS

 

10% BOILER WATER TREATMENT

 

10% DUTIES AND FUNCTIONS OF STATIONARY ENGINEERING POSITIONS

 

5% RELATED MATHEMATICS

 

THE WRITTEN EXAMINATION IS ALIGNED WITH THE MATCHING MASSACHUSETTS VOCATIONAL TECHNICAL EDUCATOR FRAMEWORKS.  SOME QUESTIONS REQUIRE A SYNTHESIS OF KNOWLEDGE BASED ON VOCATIONAL TECHNICAL WORK EXPERIENCE AND MAY NOT BE FOUND IN ANY BOOK.  HOWEVER, CANDIDATES ARE ENCOURAGED TO STUDY FOR THEIR EXAMS BY REVIEWING CURRENT TEXTBOOKS AND REFERENCE MATERIAL WHICH CAN USUALLY BE FOUND IN THE LIBRARIES OF MOST VOCATIONAL TECHNICAL SCHOOLS AND SCHOOLS WHICH OFFER CHAPTER 74 PROGRAMS.

 

*You may refer to http://www.doe.mass.edu/cte/frameworks for the Massachusetts Vocational Technical Educator Frameworks.

 


SCOPE OF TEST CODE # 43 – STATIONARY ENGINEERING

-Page 2-

 

THE FOLLOWING LIST OF REFERENCE MATERIALS WAS DEVELOPED AS A GUIDE FOR WRITTEN EXAM CANDIDATES:

 

 

Boiler Operators Workbook by Dean R. Wilson

American Technical Publishers

 

Boiler Operators Exam Preparation Guide by Theodore B. Sauselin

McGraw-Hill

 

Stationary Engineering by M. Harold J. Frost and Frederick Steingress

American Technical Publishers

 

 

YOU MAY WANT TO CHECK WITH YOUR LOCAL LIBRARY FOR OBTAINING THESE RESOURCES THROUGH THE INTERLIBRARY LOAN PROGRAM.

 

The written exam consists of 100 multiple choice questions.  Each question consists of one incomplete sentence or a questions followed by four choices.  Listed below are several sample items:

 

 

A steam pressure gauge is calibrated in :

 

            a.         btu's per pound.

            b.         pounds per cubic inch.

            c.         inches per temperature increase

*           d.         pounds per square inch.

 

A direct cause of over-heating of the boiler tubes is:

 

            a.         soot formation.

            b.         over-firing.

            c.         insufficient air.

*           d.         scale formation on the tubes.

 

 

 

 

 

 

 

 

 

* indicates correct answer

 

THE TEACHER TESTING PROGRAM WILL PROVIDE NON-PROGRAMMABLE CALCULATORS FOR USE IN COMPLETING THE WRITTEN EXAM. DOCUMENTATION REGARDING THESE CALCULATORS WILL BE INCLUDED IN YOUR ADMISSION PACKAGE.

 

10-2009


MASSACHUSETTS Vocational Technical TEACHER TESTING Program

 

SCOPE OF TEST CODE #43 STATIONARY ENGINEERING

 

PERFORMANCE EXAM

 

TIME ALLOWED:  4 HOURS

 

 

 

PERCENT OF TEST:

 

 

 

14%    Identify Boiler Fittings

 

21%    Perform Work on Steam and Water Systems

·         Repair and Rebuild Steam Trap

 

27% Treat Boiler Water

·         Obtain Water Samples From Boiler

·         Analyze water samples

·         Bottom Boiler Blow down

 

7% Perform the Duties and Functions of an Auxiliary Equipment Operator

·         Clean Oil Strainer

 

21%    Perform Maintenance Functions

·         Remove and Clean Fuel Burner Gun

·         Replace gauge glasses on water column

 

10%    Safety

·         Candidates will be evaluated for adherence to OSHA and Industry Safety Standards

 

 

THE PERFORMANCE EXAMINATION IS ALIGNED WITH THE MATCHING MASSACHUSETTS VOCATIONAL TECHNICAL EDUCATOR FRAMEWORKS.  SOME TASKS REQUIRE A SYNTHESIS OF KNOWLEDGE BASED ON VOCATIONAL TECHNICAL WORK EXPERIENCE AND MAY NOT BE FOUND IN ANY BOOK.  HOWEVER, CANDIDATES ARE ENCOURAGED TO PREPARE FOR THEIR EXAMS BY REVIEWING CURRENT TEXTBOOKS AND REFERENCE MATERIAL WHICH CAN USUALLY BE FOUND IN THE LIBRARIES OF MOST VOCATIONAL TECHNICAL SCHOOLS AND SCHOOLS WHICH OFFER CHAPTER 74 PROGRAMS.

 

 

 

*You may refer to http://www.doe.mass.edu/cte/frameworks for the Massachusetts Vocational Technical Educator Frameworks.


SCOPE OF TEST CODE # 43 – STATIONARY ENGINEERING

 

 

-Page 2 -

 

 

CANDIDATE MUST WEAR APPROPRIATE ATTIRE:

 

 

Work boots – no sneakers

Long Pants

No loose clothing or jewelry; long hair pulled back

Personal Protective Equipment (PPE) must be worn as appropriate

 

 

 

THE FOLLOWING LIST OF REFERENCE MATERIALS WAS DEVELOPED AS A GUIDE FOR PERFORMANCE EXAM CANDIDATES:

 

 

 

Boiler Operators Workbook by Dean R. Wilson

American Technical Publishers

 

Boiler Operators Exam Preparation Guide by Theodore B. Sauselin

McGraw-Hill

 

Stationary Engineering by M. Harold J. Frost and Frederick Steingress

American Technical Publishers

 

 

www.osha.gov

www.mass.gov

 

 

 

YOU MAY WANT TO CHECK WITH YOUR LOCAL LIBRARY FOR OBTAINING THESE RESOURCES THROUGH THE INTERLIBRARY LOAN PROGRAM.

 

You may refer to http://www.doe.mass.edu/cte/frameworks for the Massachusetts Vocational Technical Educator Frameworks.

 

 

 

 

 

 

 

 

 

 

 

12/2009